• DocumentCode
    2380375
  • Title

    Heart sounds based measures of cardiac status for heart failure patient management

  • Author

    Patangay, Abhilash ; Siejko, Kris Z. ; Wariar, Ramesh ; DeLurgio, David B. ; Leon, Angel R.

  • Author_Institution
    Boston Sci. Corp., St. Paul, MN, USA
  • fYear
    2009
  • fDate
    3-6 Sept. 2009
  • Firstpage
    3016
  • Lastpage
    3019
  • Abstract
    Heart sounds based measurements such as S3 amplitude and systolic timing intervals (STIs) are known to be indicative of cardiac dysfunction. In this paper we investigate the correlation of these measurements from pacemaker device implant locations to echocardiographic hemodynamic metrics of E wave deceleration time (EDT), Ejection Fraction (EF) and Stroke Volume (SV). Simultaneous heart sounds and echocardiography measurements were made in 6 heart failure patients with cardiac resynchronization therapy (CRT) devices prior to CRT activation (baseline) and at 3 and 6 months post-CRT. In N=17 datasets, S3 amplitude was correlated to EDT (r=-0.86, p<0.05). Similarly STIs such as heart sounds based pre-ejection period (HSPEP) was correlated with EF (r = -0.81, p<0.01) and ejection time (HSET) with SV (r = 0.65, p=0.01). Longitudinal analysis in each patient showed consistent changes between % increase in S3 vs. % decrease in EDT (r= -0.83, p<0.01), % change in HSPEP vs. % change in EF (r= -0.80, p=0.03) and % change in SV (r= -0.72, p< 0.01). These results show proof of concept for using pacemaker derived measurements for monitoring HF patients. Further study is needed to determine their efficacy for chronic monitoring of HF patients.
  • Keywords
    bioacoustics; biomedical measurement; echocardiography; haemodynamics; medical disorders; pacemakers; patient monitoring; CRT device; E wave deceleration time; EDT; EF; HF patient chronic monitoring; HSPEP; S3 amplitude; cardiac dysfunction; cardiac resynchronization therapy; cardiac status; echocardiographic hemodynamic metrics; ejection fraction; heart failure patient management; heart sound based measurement; heart sound based preejection period; pacemaker device; stroke volume; systolic timing intervals; Adult; Aged; Algorithms; Child; Echocardiography; Feasibility Studies; Female; Heart Failure; Heart Sounds; Humans; Male; Middle Aged; Signal Processing, Computer-Assisted; Stroke Volume; Systole;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE
  • Conference_Location
    Minneapolis, MN
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-3296-7
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2009.5332837
  • Filename
    5332837