• DocumentCode
    238262
  • Title

    Comparison of performance of induction motor fed by sine pulse width modulated inverter and multi level inverter using XILINX

  • Author

    Hirani, Manoj ; Gupta, Swastik ; Deshpande, D.M.

  • Author_Institution
    Dept. of Electr. Eng., Maulana Azad Nat. Inst. of Technol., Bhopal, India
  • fYear
    2014
  • fDate
    8-10 May 2014
  • Firstpage
    264
  • Lastpage
    269
  • Abstract
    In this paper performance characteristic of two levels and five levels inverter fed induction motor drive are compared. Open loop control of Induction motor (IM) is used in both inverter schemes. Comparison of both schemes has been done in terms of THD in their line current. Steady state response of speed, current and torque in induction motor is also compared for both control schemes. Models are developed for SPWM and Multilevel inverter fed induction motor using Xilinx.
  • Keywords
    PWM invertors; field programmable gate arrays; induction motor drives; machine control; SPWM inverter; THD; Xilinx; inverter fed induction motor drive; multilevel inverter; open loop control; sine pulse width modulated inverter; Bridge circuits; Induction motors; Inverters; Power harmonic filters; Pulse width modulation; Steady-state; Torque; Field Programmable Gate Array (FPGA); Induction Motor (IM); Multi level inverter (MLI); Sine pulse width modulation (SPWM); Xilinx;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Advanced Communication Control and Computing Technologies (ICACCCT), 2014 International Conference on
  • Conference_Location
    Ramanathapuram
  • Print_ISBN
    978-1-4799-3913-8
  • Type

    conf

  • DOI
    10.1109/ICACCCT.2014.7019443
  • Filename
    7019443