• DocumentCode
    2382896
  • Title

    Experimental studies of the RF-DC differences of voltage standards

  • Author

    Huang, De-Xiang ; He, Shui-zhi

  • Author_Institution
    Shaoxing Ind. Res. Inst., Zhejiang, China
  • fYear
    1989
  • fDate
    25-27 Apr 1989
  • Firstpage
    171
  • Lastpage
    174
  • Abstract
    The RF-DC differences (d) of primary voltage standards were determined by experimental and theoretical procedures. The voltage standards, with different operating principles and designs, have been compared with CTVCs (coaxial thermal voltage converters) at frequencies from 1 to 100 MHz. The method recommended for determining the d values is to derive an empirical formula and then to correct if from measured data. The uncertainty of primary voltage standards established by this method is ±0.007% at 1 MHz, ±0.01% at 3 MHz, ±0.02% at 10 MHz, 0.07% at 30 MHz, ±0.15% at 50 MHz, and ±0.2% at 100 MHz. This specification is shown to be reliable while leaving sufficient margin for error
  • Keywords
    measurement errors; measurement standards; voltage measurement; 1 to 100 MHz; RF-DC differences; empirical formula; measurement errors; primary standards; uncertainty; voltage standards; Bolometers; Bridge circuits; Frequency conversion; Frequency measurement; Frequency response; Heating; Testing; Thermistors; Transistors; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 1989. IMTC-89. Conference Record., 6th IEEE
  • Conference_Location
    Washington, DC
  • Type

    conf

  • DOI
    10.1109/IMTC.1989.36845
  • Filename
    36845