• DocumentCode
    2391304
  • Title

    Autoregressive spectral analysis of stabilometric signals

  • Author

    Oliveira, Liliam Fernandes ; Simpson, David Martin ; Nadal, Jurandir

  • Author_Institution
    Biomed. Eng. Program, Univ. Federal do Rio de Janeiro, Brazil
  • fYear
    1994
  • fDate
    1994
  • Firstpage
    1300
  • Abstract
    Autoregressive power spectral estimation of stabilometric signals is investigated to determine a suitable model order and sampling rate. The spectra of 30 healthy subjects were studied with a protocol of eyes open/closed and feet together/apart
  • Keywords
    biomechanics; autoregressive spectral analysis; eyes closed; eyes open; feet apart; feet together; healthy subjects; model order; sampling rate; stabilometric signals; Biomedical measurements; Eyes; Frequency; Low pass filters; Monitoring; Protocols; Sampling methods; Signal resolution; Spectral analysis; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1994. Engineering Advances: New Opportunities for Biomedical Engineers. Proceedings of the 16th Annual International Conference of the IEEE
  • Conference_Location
    Baltimore, MD
  • Print_ISBN
    0-7803-2050-6
  • Type

    conf

  • DOI
    10.1109/IEMBS.1994.415442
  • Filename
    415442