DocumentCode
2392047
Title
A 2D post-beamforming filter for contrast restoration in medical ultrasound: in vivo results
Author
Wan, Yayun ; Ebbini, Emad S.
Author_Institution
Dept. of Electr. & Comput. Eng., Univ. of Minnesota, Minneapolis, MN, USA
fYear
2009
fDate
3-6 Sept. 2009
Firstpage
1945
Lastpage
1948
Abstract
We have recently developed a robust 2D post-beamforming filter for contrast restoration in ultrasound imaging systems using coarsely-sampled array apertures, e.g. high frequency ultrasound (HFUS). The filter can be derived from a discretized 2D impulse response model in the region of interest (ROI). The key to the robustness of the regularized 2D pseudoinverse filter is transforming the operator to k-space, where the regularized inversion is implemented using 2D DFT instead of computationally intractable matrix operations. Using computer simulations, the 2D PIO was shown to produce complete restoration of contrast loss due to grating lobes resulting from coarse, 2lambda sampling of HFUS arrays in the 25-35 MHz range. In this paper, we present the first in vivo demonstration of the 2D PIO in imaging the carotid artery using a commercially available probe. The results show that the 2D PIO increases the tissue/blood contrast by 4 dB (when imaging a cross section of the vessel). These results are in agreement with experimental results obtained using the same probe in imaging quality assurance phantoms. The 2D PIO´s ability to remove the clutter from grating lobe is expected to improve the performance of speckle tracking algorithms for the estimation of tissue and blood displacements in vivo.
Keywords
array signal processing; biomedical ultrasonics; blood vessels; cardiovascular system; discrete Fourier transforms; filtering theory; image restoration; medical image processing; phantoms; 2D DFT; 2D post-beamforming filter; HFUS arrays; blood displacement; carotid artery; coarsely-sampled array aperture; computer simulation; contrast restoration; discretized 2D impulse response model; high frequency ultrasound; medical ultrasound imaging system; phantoms; pseudoinverse filter; speckle tracking algorithm; tissue-blood contrast; Algorithms; Carotid Arteries; Computer Simulation; Diagnostic Imaging; Fourier Analysis; Functional Laterality; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Linear Models; Phantoms, Imaging; Ultrasonography;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE
Conference_Location
Minneapolis, MN
ISSN
1557-170X
Print_ISBN
978-1-4244-3296-7
Electronic_ISBN
1557-170X
Type
conf
DOI
10.1109/IEMBS.2009.5333460
Filename
5333460
Link To Document