• DocumentCode
    2392634
  • Title

    A Method for Frequency Deviation Measurement

  • Author

    Agarwal, Vineeta ; Mehta, Gitanjali

  • Author_Institution
    Dept. of Electr. Eng., Moti Lal Nehru Nat. Inst. of Technol., Allahabad
  • fYear
    2006
  • fDate
    28-29 Nov. 2006
  • Firstpage
    207
  • Lastpage
    210
  • Abstract
    A simple technique is developed for measurement of power frequency deviation. It is based on multiplication of two signals having different frequencies and then filtering out the higher order frequency component. The lower order frequency component is converted into a square wave and modulated with a high frequency pulse train. The number of pulses corresponding to one time period of square wave is calibrated in terms of difference of frequency of the two signals. The results showed a linear relationship between frequency deviation and a pulse count. The technique is not sensitive to harmonic noise because of its ability to filter out all the higher order components.
  • Keywords
    frequency measurement; power system measurement; frequency deviation measurement; high frequency pulse train; square wave; Electric variables measurement; Energy measurement; Filters; Frequency conversion; Frequency measurement; Hardware; Power measurement; Power system interconnection; Power system measurements; Pulse modulation; Model Development; frequency deviation; multiplier;
  • fLanguage
    English