DocumentCode
23931
Title
Group delay measurement method based on narrow-band spread spectrum signals
Author
Zhi Bin Xiao ; Yingxiang Liu ; Xiaomei Tang ; Xiang Wei Zhu ; Feixue Wang
Author_Institution
Satellite Navig. R&D Center, Nat. Univ. of Defense Technol., Changsha, China
Volume
50
Issue
5
fYear
2014
fDate
Feb. 27 2014
Firstpage
372
Lastpage
374
Abstract
The group delay fluctuation of navigation equipment will cause signal distortion, thus bringing on ranging bias, and therfore needs to be measured and compensated. The vector network analyser method commonly adopted cannot satisfy high measuring accuracy and high frequency resolution at the same time; the higher the frequency resolution, the bigger the measuring error. To resolve this problem, a new group delay measurement method based on narrow-band spread spectrum signals is proposed. Theoretical analysis and simulation results indicate that this method can implement high measuring accuracy with any frequency resolution, and the system bias of the method is much less than 0.1 ns.
Keywords
distortion; network analysers; satellite navigation; group delay measurement method; high frequency resolution; narrow-band spread spectrum signal; navigation equipment; signal distortion; vector network analyser method;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el.2013.4029
Filename
6759682
Link To Document