Title :
Response linearization of a 2D optical position-sensitive detector
Author :
Salles, Luciana P. ; Retes, Pedro ; Fernandes, Édilla M G ; de Lima Monteiro, Davies W.
Author_Institution :
Univ. Fed. de Minas Gerais, Belo Horizonte
fDate :
Oct. 29 2007-Nov. 1 2007
Abstract :
This paper presents an alternative layout for a two-dimensional optical position-sensitive detector, namely a quad-cell, where the sensitivity (i.e. quantum efficiency) of the central region is higher than that of the peripheral region. Simulation results show that this approach improves the linearity of the quad-cell response at the central region, which is relevant in applications where high position resolution is demanded. A numerical model provides indication to an optimal spot-radius range and experimental results confirm good linearity for a spot within this range.
Keywords :
optical sensors; photodetectors; optimal spot-radius range; quad-cell response; quantum efficiency; response linearization; two-dimensional optical position-sensitive detector; Biomedical optical imaging; Optical crosstalk; Optical detectors; Optical distortion; Optical sensors; Photodiodes; Position sensitive particle detectors; Semiconductor device noise; Sensor arrays; Substrates; CMOS; PSD; optical detector; photodetector; position-sensitive detector; quad-cell;
Conference_Titel :
Microwave and Optoelectronics Conference, 2007. IMOC 2007. SBMO/IEEE MTT-S International
Conference_Location :
Brazil
Print_ISBN :
978-1-4244-0661-6
Electronic_ISBN :
978-1-4244-0661-6
DOI :
10.1109/IMOC.2007.4404324