Abstract
A simple, practical and straight-forward method to calculate uncertainty of an electric-field radiation test, using standard engineering techniques and data already at hand at a typical electromagnetic interference (EMI) test facility, is presented. Using this model to standardize the calculation of uncertainty for all measurement sites and apparatus will provide a basis to compare different laboratories and will provide insight on what and where to incorporate improvements in existing operations
Keywords
electric field measurement; electromagnetic interference; measurement errors; test facilities; EMI test facility; electric-field radiation test; electromagnetic interference test facility; measurements uncertainty calculation; radiated measurements; standard engineering techniques; Antenna measurements; Attenuation; Bandwidth; Calibration; Dipole antennas; Frequency measurement; Measurement uncertainty; Open area test sites; Receiving antennas; System testing;