Title :
The Calibrating Method of Frame-transfer Type CCD Image Smearing
Author :
Min, Wei ; HaiNing, Chen ; QinZhang, Wu ; Bin, Xu
Author_Institution :
Dept. of Comput. Sci., Chengdu Univ. of Inf. Technol., Chengdu, China
Abstract :
The Structure and imaging process of frame-transfer CCD is analyzed, Finding the image smearing is because of photosensitive unit is still exposure when image transferred line-by-line, The image subsequent lines will influent by previous lines inevitable, once there is a highlight area in image, which will generate serious image smearing. In this paper, a Calibrate image smearing method is proposed, which uses subsequent line´s gray subtract previous line´s affluence, and use this method to test several frame-transfer type CCD, experimental result shows the method simple and high efficiency.
Keywords :
CCD image sensors; image processing; CCD image smearing; calibrating method; frame-transfer; photosensitive unit; Charge coupled devices; Digital cameras; Electron optics; Information technology; Optical imaging; CCD; Calibrating method; component; frame-transfer; image smearing;
Conference_Titel :
E-Business and E-Government (ICEE), 2010 International Conference on
Conference_Location :
Guangzhou
Print_ISBN :
978-0-7695-3997-3
DOI :
10.1109/ICEE.2010.1195