• DocumentCode
    2398405
  • Title

    Induction Cell Breakdown Experiments For The Dual Axis Radiographic Hydrotest (DARHT) Facility

  • Author

    Earley, L.M. ; Barnes, G.A. ; Eversole, S.A. ; Kauppila, T.J. ; Keel, G. ; Liska, D.J. ; Moir, D.C. ; Parsons, W.M. ; Rader, D.C.

  • Author_Institution
    Los Alamos National Laboratory
  • fYear
    1991
  • fDate
    16-19 June 1991
  • Firstpage
    896
  • Lastpage
    899
  • Abstract
    Linear induction cells for the Dual-Axis Radiographic Hydrotest (DARHT) Facility have been tested to determine their high-voltage breakdown characteristics. A variety of full scale insulators were tested both in actual cells and in fixtures simulating induction cells. All insulators were constructed using cross-linked polystyrene (Rexolite). High-voltage pulses up to 550 kV were applied to the insulators using both a 60-ns pulse Blumlein and a 200-ns pulse cable Marx. Two different vacuum gaps were used in these tests, 1.46 and 1.91 cm. The tests were performed at various vacuum levels ranging from 1 x 10 -6 to 5 x 10/sup -8/ torr. Breakdown tests of the insulators were also performed with an electron beam generated in the vacuum gap through the use of a velvet emitter. The gap voltage and current were measured using calibrated E-dot and B-dot probes.
  • Keywords
    Acceleration; Electric breakdown; Electron beams; Insulation; Insulator testing; Laboratories; Performance evaluation; Radiography; Vacuum breakdown; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference, 1991. Digest of Technical Papers. Eighth IEEE International
  • Conference_Location
    San Diego, CA, USA
  • Print_ISBN
    0-7803-0177-3
  • Type

    conf

  • DOI
    10.1109/PPC.1991.733427
  • Filename
    733427