DocumentCode :
2399844
Title :
Broken rotor bars fault detection in squirrel cage induction machines
Author :
Yazidi, Amine ; Henao, Humberto ; Capolino, Gérard-André
Author_Institution :
Dept. of Electr. Eng., Picardie Univ., Amiens
fYear :
2005
fDate :
15-15 May 2005
Firstpage :
741
Lastpage :
747
Abstract :
Intensive research efforts have been focused on the signature analysis (SA) to detect electrical and mechanical faults of three-phase squirrel-cage induction machines. For this purpose, different signals can be used such as stator voltages, stator currents, stray flux and input power. The diagnosis methods based on current signals analysis (CSA) are the most popular. The interpretation of one-phase current spectrum or three-phase current space vector spectrum provides direct information on the presence of abnormal conditions. In this paper, attention has been paid to the stray flux for rotor fault diagnosis of the three-phase squirrel-cage induction machines
Keywords :
fault diagnosis; magnetic flux; rotors; squirrel cage motors; stators; broken rotor bars fault; current signals analysis; electrical faults detection; input power; mechanical faults detection; one-phase current spectrum; rotor fault diagnosis; signature analysis; squirrel cage induction machines; stator currents; stator voltages; stray flux; three-phase current space vector spectrum; Bars; Circuit faults; Electrical fault detection; Fault detection; Induction machines; Machine windings; Rotors; Stator windings; Torque; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electric Machines and Drives, 2005 IEEE International Conference on
Conference_Location :
San Antonio, TX
Print_ISBN :
0-7803-8987-5
Electronic_ISBN :
0-7803-8988-3
Type :
conf
DOI :
10.1109/IEMDC.2005.195805
Filename :
1531423
Link To Document :
بازگشت