DocumentCode :
2400046
Title :
“Brittle fracture” of composite insulators: why and how they occur
Author :
de Tourreil, C. ; Pargamin, L. ; Thévenet, G. ; Prat, S.
Author_Institution :
Abrest, France
Volume :
4
fYear :
2000
fDate :
2000
Firstpage :
2569
Abstract :
Many studies have been performed to show that the source of the acid that could produce brittle fractures in service was associated with electrical discharges. The paper shows that, although possible, this mechanism is not compatible with many observations of failed insulators. This study shows that the materials and process used for the impregnation of the glass fibers of the FRP rod can lead to the presence of acid particles that will become part of the rod. Tests have been conducted using acids derived from a rod manufacturing process. Typical brittle fractures have been obtained with insulators made with commercially available rods. This source of acid explains the brittle fractures obtained in service and agrees with the examination of failed insulators. It also explains why insulators that should have been vulnerable have not failed
Keywords :
brittle fracture; composite insulators; glass fibre reinforced composites; glass fibres; surface discharges; FRP rod; acid particles; brittle fracture; composite insulators; electrical discharges; failed insulators; glass fibers impregnation; rod manufacturing process; Delay; Fiber reinforced plastics; Glass manufacturing; Insulation; Insulator testing; Seals; Surface discharges; Tensile stress; USA Councils; Vibrations;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Engineering Society Summer Meeting, 2000. IEEE
Conference_Location :
Seattle, WA
Print_ISBN :
0-7803-6420-1
Type :
conf
DOI :
10.1109/PESS.2000.867394
Filename :
867394
Link To Document :