    A hybrid device for electrical impedance tomography and bioelectrical impedance spectroscopy measurement

  • Author

    Michalikova, Marketa ; Prauzek, Michal

  • Author_Institution
    Dept. of Cybern. & Biomed. Eng., VSB - Tech. Univ. of Ostrava, Ostrava, Czech Republic
  • fYear
    2014
  • fDate
    4-7 May 2014
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    We proposed a hybrid device, which is capable of measuring either bioelectrical impedance spectroscopy (BIS) or electrical impedance tomography (EIT) based on the Magnitude Ratio and Phase Difference Detection method. Frequency range available for measuring is from 1 kHz to 1 MHz. The device is based on The Freescale Tower system module with S08MM Freescale microcontroller. The proposed device is divided into two modules. One of them includes measurement chain, the second one contains four multiplexers, which connect always four electrodes to the circuit from total amount of sixteen electrodes. Both modules are connected via Tower elevator modules. While measuring impedance the systematic error occured, so we used the Quadratic Interpolation Self-calibration algorithm for calculation of the measured impedance. Calibration was applied on the absolute value of impedance. Calibration on the phase shift has not been done yet, since both input signals to GPD are highly disturbed with the noise, although they pass through a low-pass filter with cut-off frequency of 1 MHz. The superposed noise confuses GPD, so it cannot give the correct results. The relative error of impedance measurement after calibration ranges from -4.52 % to 5.98 % with mean value of -0.02 %.
  • Keywords
    bioelectric phenomena; biomedical electrodes; biomedical equipment; biomedical imaging; calibration; electric impedance imaging; error analysis; interpolation; modules; BIS; EIT; S08MM Freescale microcontroller; bioelectrical impedance spectroscopy; calibration; electrical impedance tomography; frequency 1 kHz to 1 MHz; impedance measurement; low-pass filter; quadratic interpolation self-calibration algorithm; relative error; the Freescale Tower system module; Calibration; Current measurement; Electrodes; Frequency measurement; Impedance; Impedance measurement; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee