Title :
Air-cooled large turbine generator with multiple-pitched ventilation ducts
Author :
Fujita, Masafumi ; Kabata, Yasuo ; Tokumasu, Tadashi ; Kakiuchi, Mikio ; Shiomi, Hidekazu ; Nagano, Susumu
Author_Institution :
Toshiba Corp., Yokohama
Abstract :
On the air-cooled turbine generators, windage loss is the substantial factor of generator losses. One solution for the windage loss reduction is to minimize the amount of coolant air with the multiple-pitched ventilation ducts in the stator core. However, non-uniform duct distribution leads to the circulating currents in the stator bar strands which increase coil losses and cause significant distribution of strand loss. This paper presents circulating currents due to multiple-pitched ventilation ducts and some schemes to reduce the circulating current loss, such as new transposition systems of coil strand
Keywords :
cooling; ducts; losses; stators; turbogenerators; ventilation; air-cooled large turbine generator; circulating currents; coil losses; generator losses; multiple-pitched ventilation ducts; nonuniform duct distribution; stator bar strands; stator core; substantial factor; transposition systems; windage loss; windage loss reduction; Coils; Coolants; Cooling; Ducts; Eddy currents; Environmental factors; Hydraulic turbines; Stator cores; Temperature; Ventilation;
Conference_Titel :
Electric Machines and Drives, 2005 IEEE International Conference on
Conference_Location :
San Antonio, TX
Print_ISBN :
0-7803-8987-5
Electronic_ISBN :
0-7803-8988-3
DOI :
10.1109/IEMDC.2005.195830