DocumentCode :
2400324
Title :
Analysis of discrepancies between measured and predicted conducted emissions in switched-mode power supplies
Author :
Kyriazis, Gregory A.
Author_Institution :
Inst. Nac. de Metrologia Normalizacao e Qualidade Ind., Brazil
fYear :
1997
fDate :
18-22 Aug 1997
Firstpage :
504
Lastpage :
506
Abstract :
An equivalent disturbance generator model that considers the snubber circuit is applied to predict the emission of a flyback-type switched-mode power supply. Common and differential mode voltages are calculated using a SPICE simulator. The conducted emission and its common mode component are measured to validate the prediction model
Keywords :
SPICE; circuit analysis computing; electromagnetic interference; snubbers; switched mode power supplies; voltage measurement; EMI; SPICE simulator; common mode voltage; conducted emissions studies; differential mode voltage; equivalent disturbance generator model; flyback-type SMPS; snubber circuit; switched-mode power supplies; Capacitance measurement; Capacitors; Coupling circuits; Diodes; Parasitic capacitance; Power measurement; Predictive models; Snubbers; Switched-mode power supply; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 1997. IEEE 1997 International Symposium on
Conference_Location :
Austin, TX
Print_ISBN :
0-7803-4140-6
Type :
conf
DOI :
10.1109/ISEMC.1997.667732
Filename :
667732
Link To Document :
بازگشت