• DocumentCode
    2401644
  • Title

    Alternative stiff asynchronous motor design for efficient pipeline operation

  • Author

    Drubel, Oliver ; Waschek, Jorg

  • Author_Institution
    SIEMENS AG I DT LD DW EN, Berlin, Germany
  • fYear
    2011
  • fDate
    28-29 Sept. 2011
  • Firstpage
    187
  • Lastpage
    191
  • Abstract
    Motor-driven pumps or compressors are required to transport fluids or gas. The efficiency of these converter driven motors can be optimized. A solution involving an optimized converter-asynchronous motor system to operate pumps and compressors with a stiff shaft has been developed and successfully tested up to 13 MW and 3000 rpm. The motor has 4 poles and is supplied with up to 100 Hz. In addition to an extensive speed range in operation, 4-pole motors have advantages in terms of reliability, efficiency and costs, which are essential features for pipeline applications and thermal power plants.
  • Keywords
    compressors; induction motors; pipelines; power convertors; pumps; reliability; 4-pole motors; compressors; converter driven motors; efficient pipeline operation; motor-driven pumps; optimized converter-asynchronous motor system; reliability; stiff asynchronous motor design; thermal power plants; Loss measurement; Position measurement; Reliability; Alternative high speed asynchronous motor design; Large electrical machines; Pipeline drive applications; Stiff motor design;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electric Drives Production Conference (EDPC), 2011 1st International
  • Conference_Location
    Nuremberg
  • Print_ISBN
    978-1-4577-1371-2
  • Type

    conf

  • DOI
    10.1109/EDPC.2011.6085568
  • Filename
    6085568