DocumentCode
2401947
Title
Effects of converter type, reset method, and core material and magamp regulator performance
Author
Tedder, Robert M.
Author_Institution
Harris Corp., Melbourne, FL, USA
fYear
1989
fDate
13-17 Mar 1989
Firstpage
391
Lastpage
400
Abstract
The magnetic amplifier (magamp) regulator´s inherent line rejection and loop performance are examined. Specifically, it is shown how the line to output rejection is affected by the reset method, core material and the driving converter topology. Equations describing magamp performance are derived and verified by measurements. Most of the tests were conducted with the magamp control loop open in order to isolate the magamp modulator rejection
Keywords
control system analysis; magnetic amplifiers; control loop; converter; core material; inherent line rejection; loop performance; magnetic amplifier; regulator performance; reset method; Delay effects; Equations; Feeds; Filters; Open loop systems; Regulators; Solids; Testing; Topology; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Applied Power Electronics Conference and Exposition, 1989. APEC' 89. Conference Proceedings 1989., Fourth Annual IEEE
Conference_Location
Baltimore, MD
Type
conf
DOI
10.1109/APEC.1989.36991
Filename
36991