Title :
Hybrid system for magnetic and acoustic measurement
Author :
Bruno, A.C. ; Baffa, O. ; Carneiro, A.A.O.
Author_Institution :
Dept. de Fis. e Mat., Univ. de Sao Paulo, Sao Paulo, Brazil
fYear :
2009
fDate :
3-6 Sept. 2009
Firstpage :
761
Lastpage :
764
Abstract :
In order to improve the spatial resolution of Biosusceptometry of Alternate Current (BAC), we are suggesting the coupling of a Doppler ultrasonic transducer with the BAC system. The Doppler transducer obtains information from the vibration of ferromagnetic particles immersed in a visco-elastic medium when it is excited by an alternating magnetic field. In this case, the same magnetic particles used as contrast for susceptometric measurement also will work as contrast for the Doppler measurement. In this work, we present the characterization of the hybrid system for susceptometric and acoustic measurements simultaneously. It was observed that the susceptometric and Doppler ultrasound signal have the same profile and maximum amplitude for frequency of magnetizing field about 200 Hz. When using ferrite particles as magnetic contrast mixed with yogurt as based material, the susceptometric and Doppler measurement have sensitivity for concentration of particles as low as 1%. The sensitivity of the Doppler is dependent of the gradient of magnetic field over the sample. In this work, the magnetic field 5 cm far from the face of the transducer was 70 muT/volts.
Keywords :
acoustic variables measurement; biomagnetism; biomedical ultrasonics; ferrite devices; ferromagnetic materials; magnetic particles; magnetic variables measurement; ultrasonic transducers; vibrations; BAC system; Doppler transducer; Doppler ultrasonic transducer coupling; acoustic measurement; alternate current biosusceptometry; ferrite particles; ferromagnetic particle vibration; hybrid system; magnetic contrast; magnetic measurement; susceptometric measurements; visco-elastic medium; yogurt; Magnetic field; Magnetic particles; Ultrasound Doppler; susceptometer; Computer-Aided Design; Equipment Design; Equipment Failure Analysis; Magnetics; Plethysmography, Impedance; Reproducibility of Results; Sensitivity and Specificity; Transducers; Ultrasonography;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE
Conference_Location :
Minneapolis, MN
ISSN :
1557-170X
Print_ISBN :
978-1-4244-3296-7
Electronic_ISBN :
1557-170X
Type :
conf
DOI :
10.1109/IEMBS.2009.5334067
Filename :
5334067
Link To Document :
بازگشت