DocumentCode :
2403052
Title :
Evaluation of the ability of nonlinear noise reduction filter to the low-contrast object in Multi-Detector Row Computed Tomography using a digital phantom and power spectrum
Author :
Kondo, S. ; Goto, S. ; Hyodo, Y. ; Maruyama, T. ; Azuma, Y. ; Matsuura, R. ; Inamura, K.
Author_Institution :
Grad. Sch. of Health Sci., Okayama Univ., Okayama, Japan
fYear :
2011
fDate :
17-18 May 2011
Firstpage :
160
Lastpage :
164
Abstract :
We propose a quantitative method to evaluate the ability of adaptive image filters for reducing noise to low-contrast objects in Multi-Detector Row Computed Tomography (MDCT). The digital phantom for evaluating the ability of a nonlinear noise reduction filter to a low-contrast object in a MDCT image was produced. The digital phantom consists of a water phantom image of MDCT and a bar pattern with a known contrast and spatial frequency. The edge-preserving adaptive filter for selectively eliminating noise in low-dose scanning known as the “Quantum Denoising System” developed by Toshiba Medical Systems was chosen as a nonlinear noise reduction filter for this paper. In this paper, two non-linear noise reduction filters, Q1 and Q2 in QDS were employed. By analyzing the power spectrum (PS) of a digital phantom, the filter performance as regards the contrast and spatial frequency of an object was investigated. The contrast-to-noise ratio from PS could express the feature of the filter briefly. That is, the validity of a filter can be shown based on the combined information of the contrast and spatial frequency of an object. Probably, this simple method will contribute to evaluating various noise reduction filters efficiently.
Keywords :
adaptive filters; computerised tomography; edge detection; image denoising; image recognition; interference suppression; nonlinear filters; phantoms; MDCT image; Toshiba medical system; contrast-to-noise ratio; digital phantom; digital power spectrum; edge preserving adaptive image filter; low contrast object; low dose scanning; multidetector row computed tomography; nonlinear noise reduction filter; quantum denoising system; spatial frequency; water phantom image; Adaptive filters; Computed tomography; Information filters; Noise; Noise reduction; Phantoms; computed tomography; digital phantom; low-contrast object; noise reduction filter; power spectrum;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Imaging Systems and Techniques (IST), 2011 IEEE International Conference on
Conference_Location :
Penang
Print_ISBN :
978-1-61284-894-5
Type :
conf
DOI :
10.1109/IST.2011.5962206
Filename :
5962206
Link To Document :
بازگشت