• DocumentCode
    2408585
  • Title

    Application of focused ion beam for testing, repair and fabrication of metal and optical interconnections in wafer scale integration

  • Author

    McDonald, J.F. ; Lin, H.T.

  • Author_Institution
    Center for Integrated Electron., Rensselaer Polytech. Inst., Troy, NY, USA
  • fYear
    1989
  • fDate
    3-5 Jan 1989
  • Firstpage
    161
  • Lastpage
    172
  • Abstract
    Testing and repair methods using a focused ion beam (FIB) system are presented. An application of ion beam voltage contrast testing to the problem of checking line continuity and shorting is examined. A microfocused secondary ion mass spectrometer is used for verification of cuts produced from ion milling. The feasibility of using FIB to micromachine optical mirrors used in optical waveguides has been studied with very encouraging results. The versatility of FIB presents a unique opportunity for test and repair of wafer-scale metal wires as well as fabrication of microoptics for optical waveguides in a single high-yield processing step
  • Keywords
    VLSI; integrated optoelectronics; ion beam applications; mirrors; secondary ion mass spectroscopy; cuts; focused ion beam; high-yield processing step; ion beam voltage contrast testing; ion milling; line continuity; metal wires; microfocused secondary ion mass spectrometer; microoptics; optical interconnections; optical mirrors; optical waveguides; repair; shorting; testing; wafer scale integration; Fabrication; Ion beams; Mass spectroscopy; Milling; Mirrors; Optical waveguides; Particle beam optics; System testing; Voltage; Wires;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Wafer Scale Integration, 1989. Proceedings., [1st] International Conference on
  • Conference_Location
    San Francisco, CA
  • Print_ISBN
    0-8186-9901-9
  • Type

    conf

  • DOI
    10.1109/WAFER.1989.47547
  • Filename
    47547