• DocumentCode
    2410296
  • Title

    Optical measurement of blood hematocrit on medical tubing with dual wavelength and detector model

  • Author

    Oshima, Shiori ; Sankai, Yoshiyuki

  • Author_Institution
    Grad. Sch. of Syst. & Inf. Eng., Univ. of Tsukuba, Ibaraki, Japan
  • fYear
    2009
  • fDate
    3-6 Sept. 2009
  • Firstpage
    5891
  • Lastpage
    5896
  • Abstract
    Blood hematocrit (Hct) is a clinically important index to detect death-dealing symptoms such as anemia and thrombosis, especially for patients with artificial heart, in dialysis and during open-heart surgery. Optical technology has been applied to monitor hematocrit noninvasively, continuously and conveniently, however, it was not well established for actual use. The purpose of this study is to develop an accurate and stable optical hematocrit measurement without any calibrations for device-mounting errors. To this end, we propose a theoretical method. In this method, disturbances are cancelled by using dual detector and optical path changes are calibrated by dual wavelength so that we can measure hematocrit without calibrations of these. Based on the method, a measurement unit that has two LEDs (805/1300[nm]) and four photo detectors was developed. Then, we performed experiments with 38 blood samples from five bovines´ blood (Hct: 19-55%). These blood samples were circulated in a mock-up circuit by a blood pump. During the experiment, we measured hematocrit on medical tubing with the developed measurement system. As a result, we could measure hematocrit within 1.7 Hct% mean errors for 38 blood samples without any calibrations. The result indicates that the proposed method is applicable for hematocrit measurement on medical tube in enough small error. We found this proposed method is effective for developments of clinically workable hematocrit measurement/monitoring system.
  • Keywords
    biomedical measurement; blood; light emitting diodes; photodetectors; LED; anemia; blood hematocrit; dual detector model; dual wavelength model; medical tubing; optical measurement; optical path; photodetector; thrombosis; Computer-Aided Design; Diagnosis, Computer-Assisted; Equipment Design; Equipment Failure Analysis; Hematocrit; Humans; Refractometry; Reproducibility of Results; Rheology; Sensitivity and Specificity;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE
  • Conference_Location
    Minneapolis, MN
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-3296-7
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2009.5334467
  • Filename
    5334467