• DocumentCode
    2411064
  • Title

    Total ionizing dose gamma and proton radiation testing on a COTS interline CCD with microlens

  • Author

    Lee, P.P.K. ; Thompson, D.A. ; Modney, D.L.

  • Author_Institution
    ITT Industries Space Syst. Div., Rochester, NY, USA
  • fYear
    2005
  • fDate
    11-15 July 2005
  • Firstpage
    163
  • Lastpage
    169
  • Abstract
    Commercially fabricated interline CCDs were total ionizing dose (TID) tested with gamma (γ) and proton (p+) radiation. Materials used for microlenses applied to the array surface were also irradiated on fused silica substrates. Device and material performance degradations are presented.
  • Keywords
    charge-coupled devices; gamma-ray effects; microlenses; proton effects; semiconductor device testing; COTS interline CCD; amplifier gain; charge transfer efficiency; dark current; fused silica substrates; gamma radiation testing; microlens materials; photodiode devices; proton radiation testing; quantum efficiency; total ionizing dose; Buffer layers; Charge coupled devices; Diodes; Ionizing radiation; Lenses; Microoptics; Photodiodes; Protons; Sensor arrays; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Radiation Effects Data Workshop, 2005. IEEE
  • Print_ISBN
    0-7803-9367-8
  • Type

    conf

  • DOI
    10.1109/REDW.2005.1532684
  • Filename
    1532684