    Effects of magnetizing current of the transformer on dynamic characteristics in the push-pull dc-to-dc converter

  • Author

    Shoyama, Masahito ; Harada, Koosuke

  • Author_Institution
    Department of Electronics, Kyushu University 36, Fukuoka 812, Japan
  • fYear
    1984
  • fDate
    18-21 June 1984
  • Firstpage
    331
  • Lastpage
    338
  • Abstract
    Dynamic characteristics of the push-pull -dc-to-dc converter are analyzed both theoretically and experimentally for the modes of operation which are caused by the interaction between magnetizing current of the transformer and that of the reactor, Among all six modes of operation, four modes are of the first order system. In two modes out of the four modes, the instantaneous reactor current does not fall to zero at any point in the switching cycle.