DocumentCode :
2418398
Title :
A high voltage cables terminator for partial discharge and dielectric loss measurement
Author :
Boonseng, C. ; Apiratikul, P. ; Nakaviwat, K.
Author_Institution :
Fac. of Eng., King Mongkut´´s Inst. of Technol., Bangkok, Thailand
fYear :
2002
fDate :
7-10 Apr 2002
Firstpage :
62
Lastpage :
65
Abstract :
This paper presents a design of the cable connector used in partial discharge and dielectric loss tests. The body of the connector is constructed using the acrylic tube and PVC, and the oil is used as an insulating medium. In order to implement the connector, partial discharges and the dielectric loss (tan δ) of a cable are tested according to IEC standards. It is found that the cable connector proposed can give the satisfactory and reasonably accurate results from the measurements. In addition, the cost of the construction of the connector developed is cheaper than that of the commercial module.
Keywords :
dielectric loss measurement; electric connectors; partial discharge measurement; power cable insulation; IEC standards; PVC; acrylic tube; cable connector; dielectric loss measurement; dielectric loss tests; insulating medium; partial discharge tests; Cables; Connectors; Dielectric loss measurement; Dielectric losses; Dielectric measurements; Loss measurement; Partial discharge measurement; Partial discharges; Testing; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation, 2002. Conference Record of the 2002 IEEE International Symposium on
Print_ISBN :
0-7803-7337-5
Type :
conf
DOI :
10.1109/ELINSL.2002.995881