DocumentCode :
2419146
Title :
Hydrophobicity recovery in silicone insulators: a closer look at testing
Author :
Frost, Nancy E. ; Krenceski, Mary
Author_Institution :
GE Corporate Res. & Dev., Niskayuna, NY, USA
fYear :
2002
fDate :
7-10 Apr 2002
Firstpage :
220
Lastpage :
223
Abstract :
Silicone polymer-based high voltage insulators enjoy an inherent advantage in their rapid return to a hydrophobic surface after electrical discharge. This work describes a close scrutiny of the factors that influence the level of surface breakdown (corona discharge time, intensity, distance of application) as well as the subsequent evaluation of the recovery (contact angle measurement technique, operator). Six sigma tools were used to identify the factors influencing test results. A reproducibility and repeatability study identified the contribution of the equipment and operator to the test results. By controlling key instrument and test method parameters, it was possible to develop a novel analysis model to predict the time to return to hydrophobic behavior that is useful in formulation development testing.
Keywords :
angular measurement; corona; insulator testing; polymer insulators; silicone insulation; analysis model; contact-angle measurement technique; corona discharge time; electrical discharge; formulation development testing; hydrophobic surface; hydrophobicity recovery; intensity; silicone polymer-based high voltage insulators; six sigma tools; surface breakdown; test method parameters; time-to return; Contacts; Corona; Dielectrics and electrical insulation; Electric breakdown; Insulator testing; Measurement techniques; Plastic insulation; Polymers; Surface discharges; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation, 2002. Conference Record of the 2002 IEEE International Symposium on
Print_ISBN :
0-7803-7337-5
Type :
conf
DOI :
10.1109/ELINSL.2002.995917
Filename :
995917