DocumentCode
2419559
Title
Flashover performance of alumina insulators in vacuum
Author
Lu, Jinzhuang ; Ding, Lijian ; Li, C.R. ; Wang, Jingchun ; Wang, Wei ; Cheng, Yangchun
Author_Institution
Dept. of Electr. Eng., North China Electr. Power Univ., Beijing, China
fYear
2002
fDate
7-10 Apr 2002
Firstpage
290
Lastpage
293
Abstract
Based on the experimental results-the trap distribution characteristic and flashover performance of alumina ceramic samples in vacuum which were prepared by different ways, this paper discusses the relationship between the trap distribution and the flashover performance of an alumina ceramic sample. Compared with the flashover performance of the insulator samples in vacuum, it was found that the trap distribution could influence the flashover performance. Based on our investigations, the relationship between the trap distribution and the flashover performance was discussed. It seems that the trap distribution may be the better parameter to reflect the flashover performance, and that further more works are needed to set up the relationship between the trap and the flashover.
Keywords
alumina; ceramic insulators; flashover; surface discharges; vacuum breakdown; Al2O3; alumina ceramic; alumina insulators; flashover performance; insulator samples; surface flashover; trap distribution; trap distribution characteristic; Breakdown voltage; Ceramics; Dielectrics and electrical insulation; Electron emission; Flashover; Shape; Stress; Surface charging; Testing; Vacuum systems;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation, 2002. Conference Record of the 2002 IEEE International Symposium on
Print_ISBN
0-7803-7337-5
Type
conf
DOI
10.1109/ELINSL.2002.995933
Filename
995933
Link To Document