  • Abstract
    Rotating machine failures due to insulation breakdown can cause catastrophic damages to the equipment, loss or de-rating of power output, lengthy forced outages and heavy costs to the utility. Therefore it is desirable to detect the onset of significant insulation deterioration and identify potential failures as early as possible. As in the medical field, regular testing and early detection of problems mean better chances of survival for the ´patient´. Faced with increasing pressure to increase unit availability yet reduce maintenance costs, utilities are moving away from time-based maintenance practices to condition-based maintenance efforts. Owners of generators and large motors are using on-line partial discharge analysis (PDA) systems for condition monitoring of the stator insulation system. Regular condition monitoring of the stator winding insulation can give users the confidence to safely operate machines, even ones that have suffered some degree of insulation degradation. This paper presents two case studies of how utilities applied an online PD testing system on a generator and a motor with insulation degradation to avoid substantial costs and forced outages. Long-term online PD monitoring has given the utilities confidence to continue running machines that have the potential for insulation failures.
  • Keywords
    computerised monitoring; condition monitoring; electric machines; insulation testing; life testing; machine insulation; machine testing; maintenance engineering; partial discharge measurement; stators; availability; case studies; condition-based maintenance; electric utilities; insulation breakdown; insulation degradation; insulation deterioration; lifetime extension experience; machine failures; maintenance costs; online PD testing; online partial discharge analysis; outages; rotating machine insulation; stator insulation system condition monitoring; Condition monitoring; Costs; Degradation; Electric breakdown; Face detection; Insulation testing; Life testing; Medical tests; Partial discharges; Rotating machines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 2002. Conference Record of the 2002 IEEE International Symposium on
  • Print_ISBN
    0-7803-7337-5
  • Type

    conf

  • DOI
    10.1109/ELINSL.2002.996001
  • Filename
    996001