DocumentCode
2422284
Title
Investigation on the low frequency dielectric response of ground-wall insulation of rotating machine windings
Author
David, E. ; Taghizad, R. ; Lamarre, L. ; Nguyen, Duc N.
Author_Institution
Ecole de Technologie Superieure, Montreal, Que., Canada
fYear
2003
fDate
19-22 Oct. 2003
Firstpage
157
Lastpage
160
Abstract
In order to assess the quality of stator winding insulation, laboratory and field instruments measuring the charge and discharge currents flowing through rotating machine ground-wall winding insulation were developed. These instruments apply a dc voltage step during a variable charging time at various voltage levels followed by a discharge step during which the insulating dielectric is shorted to ground. The current is continuously monitored during both the charge and the discharge steps. An investigation was conducted for epoxy-mica insulation systems in laboratory as well as on complete windings in the field.
Keywords
dielectric polarisation; dielectric relaxation; epoxy insulation; machine windings; mica; stators; charge currents; complete windings; discharge currents; discharge step; epoxy-mica insulation systems; ground-wall insulation; low frequency dielectric response; rotating machine windings; stator winding insulation; variable charging time; Current measurement; Dielectric devices; Dielectrics and electrical insulation; Frequency; Instruments; Laboratories; Machine windings; Rotating machines; Stator windings; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena, 2003. Annual Report. Conference on
Print_ISBN
0-7803-7910-1
Type
conf
DOI
10.1109/CEIDP.2003.1254818
Filename
1254818