DocumentCode :
2422298
Title :
Sample Clean-up of Red Fluorescent Protein for Analysis Using Electric Field in Microfluidic Device
Author :
Huh, Yun Suk ; You, Jong Kyun ; Yang, Kwangsuk ; Lee, Eun Zoo ; Hong, Yeon Ki ; Hong, Won Hi ; Kim, Do Hyun
Author_Institution :
Dept. of Chem. & Biomolecular Eng., KAIST, Daejon
fYear :
2007
fDate :
16-19 Jan. 2007
Firstpage :
1167
Lastpage :
1170
Abstract :
Microfluidic technology allows the design and operation of effective and simple devices for sample preparation and cleanup. Majority of current sample preparation methods is focused on the complex and combined steps such as solid phase extraction and membrane dialysis. In addition, it is generally recognized that sample treatment often is the bottleneck for the rapid analysis of protein due to performing off-chip in many cases. In this study, for an effective cleaning of protein from a urea-rich protein sample, electro-microfluidic desalting system was applied using the charge characteristics of protein.
Keywords :
cleaning; desalination; electric fields; microfluidics; proteins; specimen preparation; electric field; electro-microfluidic desalting system; membrane dialysis; red fluorescent protein; sample preparation; sample treatment; solid phase extraction; Biomembranes; Cells (biology); Chemical technology; Cleaning; Fabrication; Fluorescence; Microfluidics; Performance analysis; Protein engineering; Resists;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nano/Micro Engineered and Molecular Systems, 2007. NEMS '07. 2nd IEEE International Conference on
Conference_Location :
Bangkok
Print_ISBN :
1-4244-0610-2
Type :
conf
DOI :
10.1109/NEMS.2007.352226
Filename :
4160529
Link To Document :
بازگشت