Title :
Effect of real-time weighted integration system for rapid calculation of functional images in clinical positron emission tomography
Author :
Iida, Hidehim ; Bloomfield, P.M. ; Miura, Shuichi ; Kanno, Iwao ; Murakami, Matsutaro ; Uemura, Kazuo ; Amano, Masahiro ; Tanaka, Kazumi ; Hirose, Yoshiharu ; Yamamoto, Seiichi
Author_Institution :
Res. Inst. for Brain & Blood Vessels, Akita, Japan
fDate :
31 Oct-6 Nov 1993
Abstract :
A system has been developed to rapidly calculate images of parametric rate constants, without acquiring dynamic frame data for clinical positron emission tomography (PET). This method is based on the weighted-integration algorithms for the two- and three-compartment models, and hardware developments (real-time operation and a large cache memory system) in HEADTOME-IV, which enables the acquisition of multiple sinograms with independent weight integration functions. Following the administration of the radio-tracer, the scan is initiated to collect multiple time-weighted, integrated sinograms with three weight functions. These sinograms are reconstructed and the images, with the arterial blood data, are inserted into the operational equations to provide parametric rate constant images. The implementation of this method has been tested in H215O and 18F-fluorophenylalanine (18FPHE) studies based on a two-compartment model, and in a 18FDG study based on the three-compartment model. A volunteer study, completed for each compound, yielded results consistent with those produced by existing non-linear fitting methods. Thus, this system is capable of rapid generation of quantitative physiological functional images, without dynamic data acquisition, and will be of great advantage for clinical use of PET
Keywords :
image reconstruction; integration; medical image processing; positron emission tomography; 3-compartment model; 18F-fluorophenylalanine; F; H215O; H2O; HEADTOME-IV; clinical positron emission tomography; diagnostic nuclear medicine; dynamic frame data; functional images rapid calculation; large cache memory system; medical diagnostic imaging; nonlinear fitting methods; parametric rate constants; quantitative physiological functional images; real-time weighted integration system; weighted-integration algorithms; Blood; Cache memory; Data acquisition; Equations; Hardware; Image reconstruction; Nonlinear dynamical systems; Positron emission tomography; Real time systems; Testing;
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference, 1993., 1993 IEEE Conference Record.
Conference_Location :
San Francisco, CA
Print_ISBN :
0-7803-1487-5
DOI :
10.1109/NSSMIC.1993.373533