DocumentCode
2423365
Title
A study on the selection of outdoor insulators used in high altitude areas
Author
Shi, W.D. ; Guan, Z.C. ; Wang, L.M. ; Zhou, J.
Author_Institution
Dept. of Electr. Eng., Tsinghua Univ., Beijing, China
fYear
2003
fDate
19-22 Oct. 2003
Firstpage
391
Lastpage
393
Abstract
In recent years, large-scale development of China´s western region has been vigorously promoted. As part of the development, several very high voltage transmission lines have been or are planning to be built in China´s western region with a high altitude. The contamination flashover of insulators depends not only on the severity and type of contamination, but also on the altitude at which these insulators are situated. Reduced pressure or air density combined with light contamination at high altitudes decrease the flashover voltage. This paper analyzes the affects of low air pressure on the insulation characters of the transmission lines theoretically and experimentally, and a suggestion is given for the selection of outdoor insulator that will be used in the 110 kV AC power transmission line along Qinghai-Tibet railway.
Keywords
flashover; high-voltage engineering; insulator contamination; insulator testing; power overhead lines; 110 kV; Qinghai-Tibet railway; contamination flashover; high altitude areas; outdoor insulators; very high voltage transmission lines; Contamination; Flashover; Insulation; Insulator testing; Pollution; Power transmission lines; Rail transportation; Sea surface; Transmission line theory; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena, 2003. Annual Report. Conference on
Print_ISBN
0-7803-7910-1
Type
conf
DOI
10.1109/CEIDP.2003.1254875
Filename
1254875