Title :
Use of COTS components for dose rate measurement from 1 krad(SiO2)/h to 200 krad(SiO2)/h
Author :
Chambaud, P. ; Brisset, C. ; Beuzelin, G.
Author_Institution :
Commissariat a l´´Energie Atomique, Gif sur Yvette, France
Abstract :
This document describes an apparatus hardened for use in extremely high gamma radiation dose rate measurement. The basic assembly comprises a silicon detector associated with a COTS amplifier. It is supplemented by a drift compensation system.
Keywords :
compensation; gamma-ray detection; operational amplifiers; silicon radiation detectors; COTS amplifier; COTS components; Si; dose rate measurement; drift compensation system; extremely high gamma radiation dose rate measurement; silicon detector; Assembly; Circuits; Costs; Gamma ray detection; Photoconductivity; Photodiodes; Radiation detectors; Radiation hardening; Semiconductor diodes; Silicon;