• DocumentCode
    2425553
  • Title

    A Schottky receiver for nonperturbative tune monitoring in the Tevatron

  • Author

    Martin, D. ; Cliff, P. ; Fellenz, B. ; Horton, B. ; Jackson, G. ; McConnell, D. ; Shafer, R. ; Siemann, R.

  • Author_Institution
    Fermi Nat. Accel. Lab., Batavia, IL, USA
  • fYear
    1989
  • fDate
    20-23 Mar 1989
  • Firstpage
    1483
  • Abstract
    Transverse Schottky noise and coherent betatron modulation of the bunched beam revolution harmonics in the Tevatron are continuously monitored by a sensitive receiver. The electronics rely upon low-noise amplifiers, narrowband filters, and spectrally pure oscillators to obtain a minimum detectable signal of -160 dBm. Dynamic range is 80 dB. Separate baseband proton and antiproton signals are continuously analyzed in the Main Control Room
  • Keywords
    particle accelerator accessories; synchrotrons; Main Control Room; Schottky receiver; baseband antiproton signals; baseband proton signals; bunched beam revolution harmonics; coherent betatron modulation; low-noise amplifiers; minimum detectable signal; narrowband filters; nonperturbative tune monitoring; sensitive receiver; spectrally pure oscillators; transverse Schottky noise; Baseband; Dynamic range; Low-noise amplifiers; Monitoring; Narrowband; Optical modulation; Oscillators; Power harmonic filters; Protons; Signal detection;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1989. Accelerator Science and Technology., Proceedings of the 1989 IEEE
  • Conference_Location
    Chicago, IL
  • Type

    conf

  • DOI
    10.1109/PAC.1989.73487
  • Filename
    73487