Title :
Systematic error analysis and modeling of MEMS close-loop capacitive accelerometer
Author :
Dai, Gang ; Yu, Hongming ; Su, Wei ; Shao, Beibei ; Li, Mei
Author_Institution :
Inst. of Electron. Eng., China Acad. of Eng. Phys., Mianyang, China
Abstract :
This paper proposes a systematic error model for two type of structures of MEMS close-loop capacitive accelerometers, targeted to be used in micro inertial measurement unit (MIMU). The proposed model for the accelerometer´s systematic errors includes common physical parameters used to rate an accelerometer: bias, scale factor, cross-axis sensitivity and misalignment. Dynamic analysis based on the basic structure of accelerometer used to illustrate the reason and characteristics, including temperature effect, of these parameters are described. Acentric and temperature experiments show that the proposed model reduces systematic errors to nearly stochastic error level.
Keywords :
accelerometers; capacitive sensors; error analysis; microsensors; units (measurement); MEMS; MIMU; acentric; close loop capacitive accelerometer; dynamic analysis; micro inertial measurement unit; systematic error model; temperature effect; MEMS; accelerometer; error modeling; systematic error; temperature effect;
Conference_Titel :
Nano/Micro Engineered and Molecular Systems (NEMS), 2010 5th IEEE International Conference on
Conference_Location :
Xiamen
Print_ISBN :
978-1-4244-6543-9
DOI :
10.1109/NEMS.2010.5592157