DocumentCode
2429050
Title
Beam loss monitors in the SLC Final Focus
Author
Jacobsen, R.G. ; Mattison, T.
Author_Institution
Linear Accel. Center, Stanford Univ., CA, USA
fYear
1989
fDate
20-23 Mar 1989
Firstpage
1539
Abstract
Beam loss monitors in the SLC (Standford Linear Collider) Final Focus System are used for protecting accelerator and detector components, optimizing adjustment of beam halo collimators, and diagnosing beam size and halo. Construction of a variety of monitors based on discrete ion chambers, proportional tubes, continuous ion chambers, and signals from the Mark II detector is reported. The interfaces to the SLC control system, the Mark II detector data acquisition system, and the SLC machine protection system are discussed. Experience with the system during SLC commissioning and operation is reported
Keywords
data acquisition; electron accelerators; ionisation chambers; linear accelerators; particle beam diagnostics; proportional counters; Mark II detector; SLC Final Focus; SLC commissioning; SLC control system; SLC machine protection system; Standford Linear Collider; beam halo collimators; beam loss monitors; beam size; continuous ion chambers; data acquisition system; detector components; discrete ion chambers; interfaces; proportional tubes; Colliding beam accelerators; Colliding beam devices; Collimators; Control systems; Detectors; Ion accelerators; Linear accelerators; Particle beams; Protection; Structural beams;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1989. Accelerator Science and Technology., Proceedings of the 1989 IEEE
Conference_Location
Chicago, IL
Type
conf
DOI
10.1109/PAC.1989.73506
Filename
73506
Link To Document