DocumentCode
2429864
Title
Transient response of repetitive control systems
Author
Garimella, S.S. ; Srinivasan, K.
Author_Institution
Alcoa Tech. Center, PA, USA
Volume
3
fYear
1994
fDate
29 June-1 July 1994
Firstpage
2909
Abstract
Upper bounds on transient response magnitudes for a SISO continuous-time repetitive control system are derived. The need to limit the size of transients is shown to translate to limiting the amplitude ratio of the frequency response of a certain filter in the repetitive controller. The decay rate of the transients is related to the peak of a function of frequency called the regeneration spectrum, which has previously been shown in the literature to be a measure of the relative stability of the system. Bounds derived here, although conservative, can be useful in the design of the repetitive controller, as illustrated by means of an example.
Keywords
filtering theory; frequency response; periodic control; stability; transient response; SISO continuous-time repetitive control system; amplitude ratio; filter frequency response; regeneration spectrum; relative stability; transient response; transients decay rate; upper bounds; Closed loop systems; Control systems; Delay effects; Filters; Frequency estimation; Frequency response; Stability; Transfer functions; Transient response; Upper bound;
fLanguage
English
Publisher
ieee
Conference_Titel
American Control Conference, 1994
Print_ISBN
0-7803-1783-1
Type
conf
DOI
10.1109/ACC.1994.735101
Filename
735101