Author_Institution :
Mech. Dept., Ho Chi Minh Univ. of Tech. Educ., Ho Chi Minh City, Vietnam
Abstract :
The wastewater from hospital has been strongly negative affected to human life in large area. The disadvantages of the currently treatment system are low treatment efficiency, costly and unstable due to using microbiological, biochemistry, combining physics and chemistry method, or advanced oxidation process. In this study, the treatment hospital wastewater system using plasma at atmospheric pressure was designed and developed to solve the above disadvantages. Wastewater from the three clinic centers Long Binh, Y Đuc, and Sai Gon Lab. were used and the densities of BOD5, COD, Nitrat, Phosphat, Coliforms were studyed. Applied voltage, applied current and treatment time were used for analyse the treatment efficiency. The results show that treatment efficiency of BOD5, COD, Phosphat, NO3- and coliforms are 54%, 51%, 50%, 60%, and 99,9%, respectively. The treatment efficiency is about 35% at 30KV applied voltage, 4A applied current and 0.12s. The treated wastewater reaches to B-QCVN 28:2010 standards at 0.7s treatment time.
Keywords :
atmospheric pressure; biochemistry; hospitals; oxidation; wastewater treatment; BOD5; COD; Coliforms; NO3; Nitrat; Phosphat; advanced oxidation process; atmospheric presure; biochemistry method; coliforms; combining physics method; current 4 A; hospital wastewater treatment system; microbiological method; time 0.12 s; time 0.7 s; treatment efficiency; voltage 30 kV; Chemicals; Educational institutions; Hospitals; Oxidation; Plasmas; Standards; Wastewater; advanced oxidation process; hospital wastewater; plasma technology;