DocumentCode :
2434294
Title :
The technique of microwave multiport transducer calibration
Author :
Guimpilevich, Y.B. ; Vertegel, V.V.
Author_Institution :
Sevastopol State Tech. Univ., Ukraine
fYear :
2000
fDate :
11-15 Sept. 2000
Firstpage :
487
Lastpage :
489
Abstract :
Technique of calibration of the multiport microwave transducer, which is intended for an automatic network analyzer, is described. The mathematical model for a multi-port transducer is represented. Expressions for determination of equivalent complex parameters of the transducer are derived.
Keywords :
S-parameters; calibration; microwave measurement; multiport networks; network analysers; transducers; automatic network analyzer; equivalent complex parameters; microwave multiport transducer; transducer calibration; Calibration; Gas insulated transmission lines; Helium; IEEE catalog; Microwave theory and techniques; Organizing; Transducers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Conference, 2000. Microwave and Telecommunication Technology. 2000 10th International Crimean
Conference_Location :
Crimea, Ukraine
Print_ISBN :
966-572-048-1
Type :
conf
DOI :
10.1109/CRMICO.2000.1256193
Filename :
1256193
Link To Document :