• DocumentCode
    2435272
  • Title

    Film Bulk Acoustic-Wave Resonator based radiation sensor

  • Author

    Oiler, Jonathon ; Qiu, Xiaotun ; Zhu, Jie ; Wang, Ziyu ; Yu, Cunjiang ; Barnaby, Hugh ; Holbert, Keith ; Yu, Hongyu

  • Author_Institution
    Sch. of Earth & Space Exploration, Arizona State Univ., Tempe, AZ, USA
  • fYear
    2010
  • fDate
    20-23 Jan. 2010
  • Firstpage
    967
  • Lastpage
    970
  • Abstract
    This paper describes a high-energy electromagnetic wave radiation detection device using zinc oxide (ZnO) based Film Bulk Acoustic-Wave Resonator (FBAR). The resonant frequency of the FBAR decreased after gamma radiation, with the peak sensitivity of 9.3 kHz/krad and minimum detectable dosage of 218 rad occurring at the lowest experimental dose of 20 krad (all dosages are calibrated with ZnO), while the sensitivity decreased with increasing total ionizing dosage. The incident radiation generated charges that was trapped near the ZnO-silicon nitride (SiN) interface, which increased the plate capacitance of the FBAR, resulting in the decrease of resonant frequency.
  • Keywords
    acoustic resonators; bulk acoustic wave devices; gamma-rays; radiation detection; radiation hardening (electronics); silicon compounds; zinc compounds; FBAR plate capacitance; FBAR resonant frequency; SiN; ZnO; electromagnetic wave radiation detection; film bulk acoustic wave resonator; gamma radiation; incident radiation; radiation sensor; total ionizing dosage; Film bulk acoustic-wave resonator; dosimeter; frequency shift; radiation sensor;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nano/Micro Engineered and Molecular Systems (NEMS), 2010 5th IEEE International Conference on
  • Conference_Location
    Xiamen
  • Print_ISBN
    978-1-4244-6543-9
  • Type

    conf

  • DOI
    10.1109/NEMS.2010.5592605
  • Filename
    5592605