• DocumentCode
    2436317
  • Title

    Electrical impedance spectral measurements of muscular tissue in different physiological condition

  • Author

    Clemente, Fabrizio ; Cesarelli, Mario ; Bifulco, Paolo

  • Author_Institution
    Ist. di Ing. Biomed., Rome, Italy
  • fYear
    2012
  • fDate
    18-19 May 2012
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Electrical Impedance Spectroscopy (EIS) has been applied for tissue evaluation in different clinical fields. The aim of this study is to characterize the electrical properties of muscular tissues and its variation due to a prolonged contraction and successive relaxation. The layout of measurement has been studied. Preliminary results show significant differences in the characterization of impedance data in the different examined situations.
  • Keywords
    bioelectric phenomena; biomedical measurement; electric impedance measurement; muscle; clinical fields; electrical impedance spectral measurements; electrical properties; muscular tissue; physiological condition; prolonged contraction; tissue evaluation; Biomedical measurements; Frequency measurement; Impedance; Impedance measurement; Instruments; Muscles; Biomedical equipment; Biomedical monitoring; Impedance measurement; Muscle;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Medical Measurements and Applications Proceedings (MeMeA), 2012 IEEE International Symposium on
  • Conference_Location
    Budapest
  • Print_ISBN
    978-1-4673-0880-9
  • Type

    conf

  • DOI
    10.1109/MeMeA.2012.6226624
  • Filename
    6226624