DocumentCode
2438822
Title
Effect of Environmental Temperature on the Airflow Gyroscope
Author
Piao, Lin-Hua ; Li, Yan-Jie ; Li, Bai-Hua ; Zhang, Fu-Xue
Author_Institution
Beijing Key Lab. for sensor, Beijing Inf. Sci. & Technol. Univ., Beijing, China
Volume
2
fYear
2009
fDate
26-27 Aug. 2009
Firstpage
316
Lastpage
319
Abstract
The temperature and fluid fields in a sense organ with different environmental temperatures are calculated by using Finite Element Method. The results are as follow: In a constant input of angular velocity, the temperature and fluid fields change with environmental temperature and fluid fields change with environmental temperature; The airflow rate difference of two detecting hot wires minishes with temperature increasing, and detection bridge´s output voltage decreases too, leading to impreciser sensitivity ; Conversely, the airflow rate difference of two hot wires increases with temperature decreasing, and the output voltage increases too, leading to preciser sensitivity; The average change rate of sensitivity with temperature is 0.0336 mV/deg/S/degc, when the angular rate is 20deg/S.
Keywords
finite element analysis; gyroscopes; airflow gyroscope; airflow rate; angular velocity; environmental temperature; finite element method; preciser sensitivity; Angular velocity; Finite element methods; Gyroscopes; Intelligent sensors; Intelligent systems; Man machine systems; Platinum; Temperature sensors; Voltage; Wires;
fLanguage
English
Publisher
ieee
Conference_Titel
Intelligent Human-Machine Systems and Cybernetics, 2009. IHMSC '09. International Conference on
Conference_Location
Hangzhou, Zhejiang
Print_ISBN
978-0-7695-3752-8
Type
conf
DOI
10.1109/IHMSC.2009.202
Filename
5335977