DocumentCode
2442247
Title
Improvements of Josephson voltage standard in national metrology centre (NMC) Singapore
Author
Sim, T.Y. ; Tan, V.K.S. ; Liu, L.X.
Author_Institution
Nat. Metrol. Centre, Singapore Inst. of Stand. & Ind. Res., Singapore
fYear
1996
fDate
17-21 June 1996
Firstpage
238
Lastpage
239
Abstract
This paper describes the recent performance upgrading of Josephson voltage standard in NMC. It consists of measures to keep the frequency stability of microwave source within /spl plusmn/1 Hz, proper ways of shielding and grounding to minimise spontaneous step transitions during a measurement and methods to reduce combined uncertainty by 10%.
Keywords
Josephson effect; earthing; electromagnetic shielding; frequency stability; measurement errors; measurement standards; microwave measurement; superconducting junction devices; voltage measurement; Josephson voltage standard; Singapore; combined uncertainty; frequency stability; grounding; microwave source; national metrology centre; performance upgrading; shielding; spontaneous step transitions; Current measurement; Diodes; Electrical resistance measurement; Energy measurement; Frequency measurement; Metrology; Microwave measurements; Stability; Thermal resistance; Voltage measurement;