    Characterization and optimization of a flash X-ray source for dense spray radiography

  • Author

    Romero, E. ; Cachoncinlle, C. ; Robert, E. ; Viladrosa, R. ; Coudrat, G. ; Dozias, S. ; Pouvesle, J.M.

  • Author_Institution
    GREMI-Polytech´´Orleans, Orleans
  • fYear
    2008
  • fDate
    15-19 June 2008
  • Firstpage
    1
  • Lastpage
    1
  • Abstract
    Summary form only given. Liquid sprays analysis, as those generated by fuel injection systems, implies diagnosis procedures able to produce information for matter in different phases from liquid to vapor. The high speed sprays produced by the fuel injection systems, need a fast and reliable diagnosis technology. Previous works on N2 cryogenic jets in a high pressure chamber had shown that the use of flash X-ray system can provide valuable data over wide range of parameter conditions. The flash X-ray (called DIKEV), is a transportable blumlein table top source build at GREMI laboratory to perform radiography of fuel injection sprays. This device delivers high X-ray doses, a few mGy per pulse at the output window, in pulses of tens of nanoseconds duration and operates from single shot up to 50 Hz repetition rate. DIKEV efficiency optimized for charging voltage ranging from 10 to 25 kV, leads to the production of X-ray photons with energy ranging from 5 to 40 keV. The low part of this photon energy range, where most photon are produced , is matched for the radiography of dense spray of light elements. The X-ray focus size is not controlled by electrostatic grids as in case of conventional X-ray tubes, but is correlated with the pulsed electric field topography in the X-ray diode. A significant reduction of the X-ray focus size was achieved. This have been possible thanks to the high efficiency of the carbon fiber as field emitter cathode; which permitted an important reduction of cathode size (graphite rods of diameter ranging from 0.5 mm to 2 mm and 10 mum carbon fiber) without dose reduction up to 1000 shots. The density calculation from Beer Lambert´s law, requires the precise knowledge of X-ray spectrum. For four different metallic anodes, a DIKEV full spectra characterization has been made with a germanium photodetector. The most important K,L characteristics lines below 30 keV for each anode were identified together with Bremsstrahlung spectra. In con- - trast to Mo case where continuum spectrum is dominant, a very high, characteristic line to Bremsstrahlung ratio was measured for Cu anode. Best anode material can be easily selected to be adapted to given spray characteristics.
  • Keywords
    carbon fibres; copper; fuel systems; germanium; high-speed techniques; molybdenum; photodetectors; plasma X-ray sources; radiography; Beer Lambert law; C; Cu; Ge; Mo; X-ray diode; X-ray focus size; carbon fiber; cathode size; dense spray radiography; diagnosis technology; field emitter cathode; flash X-ray source; fuel injection systems; germanium photodetector; graphite rods; high speed sprays; liquid sprays analysis; metallic anodes; photon energy; pulsed electric field topography; size 0.5 mm to 2 mm; size 10 mum; voltage 10 kV to 25 kV; Anodes; Carbon dioxide; Cathodes; Cryogenics; Diagnostic radiography; Fuels; Information analysis; Laboratories; Nanoscale devices; Spraying;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Plasma Science, 2008. ICOPS 2008. IEEE 35th International Conference on
  • Conference_Location
    Karlsruhe
  • ISSN
    0730-9244
  • Print_ISBN
    978-1-4244-1929-6
  • Electronic_ISBN
    0730-9244
  • Type

    conf

  • DOI
    10.1109/PLASMA.2008.4591119
  • Filename
    4591119