Abstract
Fault detection and identification techniques based on bond graphs have proved their importance in many engineering fields. In order to apply these techniques to complex electronic and mechatronic systems, it is necessary to have bond graph models of electronic devices. In this paper a model is obtained, which reproduces the behavior of an inverter using an operational amplifier, both under normal and faulted operation conditions. The model is validated against other models currently accepted.
Keywords
bond graphs; fault location; mechatronics; operational amplifiers; bond graph; electronic systems; fault detection; fault identification; fault modeling; mechatronic systems; operational amplifier circuits; Bonding; Circuit faults; Circuit simulation; Differential amplifiers; Fault diagnosis; Frequency; Impedance; Inverters; Operational amplifiers; Voltage;