DocumentCode
2449277
Title
A microwave two-way time transfer experiment
Author
Liao, C.S. ; Cheng, T.Y. ; Lin, S.Y. ; Lin, H.T.
Author_Institution
MOTC, Tecommunication Lab., Tao-Yuan, Taiwan
fYear
1996
fDate
17-21 June 1996
Firstpage
299
Lastpage
300
Abstract
Comparisons of BSF time and UTC(TL) for time keeping have continued in Taiwan for years. A microwave two-way, time and frequency transfer experiment without using the spread spectrum technique performed between TL and BSF broadcast station is reported. The result showed that the stability was less than 5 ns.
Keywords
delays; frequency measurement; measurement standards; microwave links; synchronisation; time measurement; 1 MHz; BSF time; Universal Time Scale; flying clock trip; frequency transfer; microwave communication; microwave link; microwave two-way time transfer; signal pulse distortion; stability; synchronization; time delay; Clocks; Distortion; Frequency; Laboratories; Microwave communication; Microwave theory and techniques; Radio broadcasting; Spread spectrum communication; Time measurement; Transmitting antennas;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 1996 Conference on
Conference_Location
Braunschweig, Germany
Print_ISBN
0-7803-3376-4
Type
conf
DOI
10.1109/CPEM.1996.547082
Filename
547082
Link To Document