• DocumentCode
    2451031
  • Title

    Amp-hour counting charge control for photovoltaic hybrid power systems

  • Author

    Hund, Thomas D. ; Thompson, Bruce

  • Author_Institution
    Sandia Nat. Labs., Albuquerque, NM, USA
  • fYear
    1997
  • fDate
    29 Sep-3 Oct 1997
  • Firstpage
    1281
  • Lastpage
    1284
  • Abstract
    An amp-hour counting battery charge control algorithm has been defined and tested using the Digital Solar Technologies MPR-9400 microprocessor based photovoltaic hybrid charge controller. This work included extensive laboratory and field testing of the charge algorithm on vented lead-antimony and valve regulated lead-acid batteries. The test results have shown that with proper setup, amp-hour counting charge control is more effective than conventional voltage regulated sub-array shedding in returning the lead-acid battery to a high state of charge
  • Keywords
    battery chargers; battery storage plants; microcomputer applications; photovoltaic power systems; power system control; secondary cells; solar power stations; MPR-9400 microprocessor; Pb; Pb-Sb; amp-hour counting charge control; battery charge control algorithm; field testing; laboratory and field testing; photovoltaic hybrid power systems; secondary battery charging; voltage regulated sub-array shedding; Acceleration; Batteries; Control systems; Laboratories; Manufacturing; Phased arrays; Photovoltaic systems; Solar power generation; System testing; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Photovoltaic Specialists Conference, 1997., Conference Record of the Twenty-Sixth IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    0160-8371
  • Print_ISBN
    0-7803-3767-0
  • Type

    conf

  • DOI
    10.1109/PVSC.1997.654322
  • Filename
    654322