Title :
10:1 ratio transformer for capacitance measurement
Author :
Nakamura, Y. ; Fukushima, A. ; Kinoshita, J. ; Sakamoto, Y. ; Endo, T.
Author_Institution :
Electrotech. Lab., Ibaraki, Japan
Abstract :
A 10:1 ratio transformer has been fabricated as a part of key elements to re-establish the capacitance standard at ETL. From the results of the calibrations, the offset from the nominal 10:1 ratio of our transformer has been obtained as 1.6/spl times/10/sup -8/ for inphase and 8.15/spl times/10/sup -7/ for quadrature with the reproducibility of the order of 10/sup -9/.
Keywords :
bridge instruments; calibration; capacitance measurement; measurement standards; transformers; 10:1 ratio transformer; ETL; calibrations; capacitance bridge; capacitance measurement; capacitance standard; quadrature bridge; Bridge circuits; Calibration; Capacitance measurement; Connectors; Electrical resistance measurement; Laboratories; Measurement standards; Switches; Voltage measurement; Wounds;
Conference_Titel :
Precision Electromagnetic Measurements Digest, 1996 Conference on
Conference_Location :
Braunschweig, Germany
Print_ISBN :
0-7803-3376-4
DOI :
10.1109/CPEM.1996.547116