DocumentCode
2452890
Title
Thermal analysis of a high-speed generator
Author
Aglén, O. ; Andersson, Å
Author_Institution
Dept. of Electr. Eng., R. Inst. of Technol., Stockholm, Sweden
Volume
1
fYear
2003
fDate
12-16 Oct. 2003
Firstpage
547
Abstract
The machine under study is a permanent magnet synchronous generator intended for operation at high speeds together with a micro-turbine in a combined heat and power (CHP) unit. Target power is 110 kW at 70000 rpm. The study is both theoretical and experimental since it includes calculation of loss distribution and thermal analysis together with calorimetric measurements of losses and temperature measurements. In this paper the thermal model is described. Using results from loss calculation and calorimetric measurements a thermal analysis is carried out. It is shown that introducing a copper screen in the rotor reduces the losses to acceptable values. A limit for the allowable rotor losses is given.
Keywords
calorimetry; cogeneration; gas turbines; loss measurement; permanent magnet generators; synchronous generators; thermal analysis; 110 kW; CHP unit; calorimetric losses measurements; combined heat and power unit; copper screen; high speed operation; high-speed generator; loss distribution; micro-turbine; permanent magnet synchronous generator; rotor; rotor losses reduction; temperature measurements; thermal analysis; Cogeneration; Magnetic analysis; Magnetic separation; Permanent magnets; Power generation; Power harmonic filters; Rotors; Shafts; Stator cores; Synchronous generators;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Conference, 2003. 38th IAS Annual Meeting. Conference Record of the
Print_ISBN
0-7803-7883-0
Type
conf
DOI
10.1109/IAS.2003.1257554
Filename
1257554
Link To Document