DocumentCode :
2453836
Title :
Fault detection and diagnosis of six-phase voltage source inverter using trajectory mass current center
Author :
Foito, D. ; Pires, V.F. ; Maia, J. ; Martins, J.F.
Author_Institution :
EST Setubal, Inst. Politec. Setubal, Setubal, Portugal
fYear :
2012
fDate :
3-5 Oct. 2012
Firstpage :
243
Lastpage :
246
Abstract :
This paper presents a new fault detection and diagnosis method for a six-phase voltage source inverter (VSI). The proposed method is based on an equivalent six dimension of a current trajectory mass center of the VSI output currents. This approach allows detecting and identifying the faulty power switch. The proposed approach results in a fast and reliable fault detection method. The performance of a proposed technique, are confirmed through several simulation and experimental results.
Keywords :
fault diagnosis; invertors; switches; VSI; fault diagnosis; faulty power switch; reliable fault detection method; six-phase voltage source inverter diagnosis; trajectory mass current center;